Oxygen not included cooling loop. If you need to, vent excess hydrogen to space.

Oxygen not included cooling loop When you start building active cooling machines, you can build full fledged condensators to entirely condense the steam. You will need external power as the AT-ST will probably not be able to power itself when the geyser is dormant. But it is better to use separate cooling loop to cool the plant than bother cooling the water directly. A popular optimization many players do is having the overflow bridge on the polluted side, and have it run to 1-2 hydroponic farm tiles planted with Thimble Reeds. One thing to take note off is that this build is not energy efficient at all. In this case, a single water line runs the entire width of the map for all the robominers in space. You can easily chill it down to 0°C when you electrolyze the normal polluted water or salt water pools for example (and those last for hundreds of cycles). Im in 1560 cycle and I need cool water. so i i made this cooling loop with a couple of aqua tuners. It seems there is a way to use automation to close off the pipe going to an aquatuner if the liquid is so cold it would freeze and cause pipe damage. If I decide one day it's against my morals to use infinite gas storage containers, you could build a room with CO2, and another one with chlorine, cool them as low as you can with PH2O and then pump them to a holding tank where you run ethanol through it cooling it to a liquid. saw a video where someone was using water or oil, someone said best to use supercoolant because you would use less energy to cool it but will get back more energy from steamturbine. They're not ideal for constant cooling, but rather for stuff like getting an overheated room back to manageable temperatures, solidifying phosphorus for pip farms, or even just getting an insulated farm room to the right temperature before you plant. Jan 20, 2022 · This is the standard design for the Steam Turbine and Thermo Aquatuner buildings in Oxygen Not Included. Locate refinery in a separate cold biome. I want the polluted water to cycle through the refinery until it hits X temp. (Cooling loop - so, steel and plastic - required. If you need to, vent excess hydrogen to space. Considering the 2 first factors your cooling loop has never had even a small chance to be fast at cooling. Does anyone have a set of reliable instructions for building such a system within the game? (to be used for cooling). In this way you can run a cooling loop through the vacuum of space, keeping machines up there nice and chill. Basically it involves a building that deleted heat (the Steam Turbine) there aren't really many other reliable methods that don't use some exploit or quirky mechanic. Always have enough storage, don’t let the system lock up. The water in the reservoir i used as cooling for a metal refinery in a closed loop so i dont need to power a pump. Since i don't understand the games liquid plubing mechanics 100% yet, im not sure why sometimes the The food sits in a vacuum to prevent heat exchange between the water, oxygen and tile. Build your base in a dome shape, with a funnel at the top and the hydrogen can automatically be separated from the oxygen. Jul 24, 2020 · yeah for my primary chamber for cooling, i like to use a lot of water, smaller ones i like to control the amount actively in the chamber so it avoid over cooling it and stopping power production (for consistency in my power grid production). Before every aguatuner is a liquid sensor. It will take time for it to cool down at first, but over time it should catch up. But the amount of heat each packet can remove is 100% dependent on the SHC of the coolant, and the more than twice higher SHC of water compared to crude means a water/pwater aquatuner cooling loop will always remove more than twice as much heat as a crude cooling loop. It goes shutoff - flow control (set at 400g again arbitrary, just very low to maximize the amount of heat the coolant draws in) -> then dumping into the hot tank. For example, the cooling loop that cools my industrial section has a pressure sensor of 1000g above which it opens a diversion to the condenser coil. In a volcano tamer, you probably want 30-50 kg of steam (not water) or more in each tile. The Electrolyzer's Hydrogen output is used to Power the construction; periodic excess Hydrogen will be emitted from the SPOM over time. Jul 27, 2019 · So I came across this and replicated it for my base's cooling loop, but found that it had a problem with non-full pipes in that the liquid would keep circulating and dip below the desired temperature because it always does one run through the aquatuner (and I'd rather not have my polluted water f This means that your solution consumes ~2. Maybe a pressure sensor? If so, where would I put it, and where should I divert the water to? I'm trying to figure out how to attach a screenshot, and I don't see any way to do so. Maybe that's the first problem I need to solve. Aug 3, 2023 · Welcome to another tutorial for Oxygen Not Included! Today we go over actually getting a cooling loop into the base and connect the SPOM to the main grid. . Still early enough stages so dont need an industrial cooling loop yet. For a more permanent cooling solution, you can create a loop of water Hi! I'm trying to create a cooling water loop with a liquid shutoff but it's not working as expected and I don't understand why. Hop Wether you want to warm it up or cool it down, the answer is a cooling loop. Jun 17, 2019 · title^ aquatuner under steamturbine. ----- Personally I never experienced such stuff but Il keep that in mind, so thanks for the heads up. your liquid vents are in the middle thus it deposits the water back there. Run your liquid cooling loop through the walls and floors of your base, not the air. Perfe Sep 7, 2019 · ah, this explains a lot, thanks guys. As with everything else in Oxygen Not Included, there are many ways you can do things. (Or use the plumber skill to empty a pipe without deleting it. Otherwise it will overheat. Dec 4, 2019 · The water used for cooling is polluted water from a slime biome. It works well for instance with a SPOM, feeding in oxygen for cooling and excess hydrogen from the SPOM to power the cooling loop. Its set on 15 degrees First time trying to build a conveyor loop to have regolith transfer its heat into a steam chamber. Fill the loop while the aquatuner can't turn on and then disconnect the bridge before allowing the aquatuner to turn on. 537DTUs) instead of something like 10% of 50'c (145'c -> 95'c) which inputs 20. Do y'all cool the output oxygen? No, stop it, it's useless. everything runs smoothly my question is that i run my cooling pipes through isolated tiles. I set up a second loop using a shutoff valve that closes when it's cool enough, but I end up with alternating hot and cold bubbles and it misses some of them. Base cooling is a pressing issue at all times. Plus I am planning to do a very weird run and without getting too much into the details in this run I would have access to lots of ethanol, and since it has such a low freezing point I was wondering if it could be any good as a coolant. You are running heavy-watt wire into the steam chamber, which means you'll be leaking heat to the outside that has to be cooled by the same cooling loop, which reduces effectiveness drastically. Cooling O2 by running the same cooling loop you use to cool your base through the SPOM is generally not difficult and doesn't take much effort to implement. Also sometimes it just gets stuck, so I I've just tried my first build with an thermo tuner if it gets below a certain temp. I usually find that I need to modify the cooling loop at some point as my base changes, so making that easy to do is a plus. Your Duplicants will need water, Loop B = radiant pipe in SPOM to cool oxygen going to base. do you have ice nearby? Anti entropy thermo-nullifier cooling loop. If a layer of oxygen gets trapped between the steam and turbine the system will overheat and break. In this episode, we build a cooling loop for the base and machine block. If you want to heat up the farm, make so the other end of the cooling loop snakes through water warmed up to the temperature you want, with a tepidizer+temperature sensor combo. just to be clear, the take away is to not flip the AT because of these "1-sec hiccups", make sure the output of the bridge is directly adjacent to the AT if using a bridge at all for your bypass like Saturnus said, and finally, do not overfill the cooling loop to block the system as the AT can store a packet within itself, thanks for the vid bzgz. for the smaller ones i try to keep steam pressure jsut above 100KG per tile so if i need inside of it I've copied it identically, almost, but the cooling period seems to be just barely enough to get it to a cool temp, i was really hoping to have sub-zero degree oyxgen to assist with base cooling. The pipe is insulated everywhere except over the tile you're trying to cool, where it is a radiant pipe. SHC matters. I cant cool down my water under 33 degrees. This stops working when I connect the lower conveyor rail to the loop Ensure the cooling loop is all the same liquid and that the sensor for the pipes is set at least 11C above the freezing point of your cooling fluid. The only good use of cool water that I can think of is for farming. Probably the best way of early game cooling is to build a little pool near the generator, then store the created ice in a storage container in that pool, letting it thaw and produce puddle of cold water that'll continue cooling the area until it warms up (to avoid getting flooded, limit the storage container to at most what the pool can handle). The problem is I get like 140 degree output, because one round through an aquatuner only cools it 14 degrees. On the other hand, the steam heat offsets the power consumption for a water aquatuner by about 50%. You can run those pipes through flours or out in the open, it just needs to reach a large Nov 4, 2022 · This translates to 14 C of cooling for Oxygen, allowing a net total of 42 C cooling to be applied if the Oxygen throughput were exactly 1 kg/s. And Tu The one main advantage of the Ice-E fan is that it allows you to relatively quickly cool an area with little investment into infrastructure. If you are using a shorter cooling loop you need to limit the total amount of coolant to a maximum of 800kg + number of pipe segments on the loop x 10kg. As long as the items on the top right temperature sensor are above a certain temperature, they stay inside the loop. What I did was split the capacity of the line - so 1000g packets ran out of the source (electrolyzer setup in my case) through a valve to bring them down to say 650g before going into the first . Locate the oil refinery far away from the base. So, either get rid of reservoir and play around with filling the loop exact amount of 1kg per pipe segment, or stop this perversion and use soopercoolant. the cooling loop cools the turbines and the heat produced by the refinery and all the equipment, its uptime is around 10-20% in polluted water. i was wonderi If you have a place that needs a small amount of cooling, but there’s already a maze of pipes there, try this: Create a cooling loop using polluted water, and use it to cool a tank of water, to use as a heat exchanger Create a hydrogen-based cooling loop, and run it through the cold tank, through the area you want to cool. You need to put the temp sensor onto the cooling loop so it tracks flowing water. I When the aquatuner turned on, another packet was able to enter the loop, and when the aquatuner turned off, the loop got stuck. Oct 27, 2020 · An AETN works pretty well for cooling oxygen when the water is cooler. Removing the bridge used to fill the loop frees up the pipe section that the bridge output is landing on and ensures the cooling loop sees green to white rather than green to green. The exit point of the bridge needs to be part of the loop. The entire loop is full of water, there are 4 storage tanks that help the cooling process by forcing all of the stored water to reach an average temperature so that all the water packets are consistent. So why ethanol? Cooling Loop Blueprint is part of a series dedicated to providing prefabs and guides for recent and long time players of Oxygen Not Included. In the case where one Dupe will "always" be operating a Refinery or a group of Refineries on a cooling loop, using up coolant faster than 10 kg/s averaged over each batch, that single loop bottleneck of 10 kg/s is the process rate limit for sure. Jun 5, 2023 · The cooling loop is a thermal aquatuner in a steam chamber cooling system. So 85kg of water per tile is 17 kg of steam per tile if your room is 5x3 (a size I prefer for steam boxes. Why are you asking about evaporation? A cooling loop should never empty packets of liquid out into the environment. TC is irrelevant. Since you're using the cooling loop to cool the turbine, the deleted steam heat will delete some heat that would otherwise go into the aquatuner, but only at a 10% conversion rate. i have a Aluminum volcano tamer with a conveyor loop. Self cooling systems need the steam to be inputed into the turbine near it's minimum temperature (125'c), that way the heat input into the turbine is about 10% of 30'c (125c -> 95% of heat (or 12. Hello everyone! Today, we're going to do a tutorial on how to set up your steam turbines and aqua tuners the right way to make cooling in your base easy. And pwater is a better coolant than petroleum unless you are running your coolant at high temps. Your floor tiles have a much higher mass and a much higher specific heat capacity, which is why you sho You need to change your cooling loop to include the steam turbine. Just a long loop of polluted water with a small part of radiant pipe near the cold section, the rest is normal pipe granite. I believe its very good design. I need 29 max due to my flowers. I've a a loop of two aquatuners to cool water for my farms, but occasionally a packet gets past my automation and is cooled below 0, breaking the exit pipe. I hope you find Apr 10, 2021 · I was reading about some more advanced builds while using the thermo aquatuner. Yes but the cooling loop would be "connected" to the hydrogen, temperature-wise. OR remove any bridge that you used to feed the cooling loop. Anyway, in the basic design, such as the one shown in the video, the temp is at around 125C so oil isn't needed, it won't even get close to 175C. For the white port, the piping should go from the tuner, to the first, then second bridges, then stop at the left most bridge. They can be sufficient if you're just using the turbine to delete heat and not generating much power. These buildings have a natural synergy with each oth Hi Guys here is the "regular" steel Setup for the Aquatuner with a Steam Turbine. Some of the packages are too little (mg or mcu) for heat exchange and it blocks my rail, as far as I know rails have to work as pipes, but the Do you mean the pipe loop or the aquatuner steam room? For steam room, do the math. Community for the space-colony simulation game Oxygen Not Included, developed by Klei. You're splitting the petroleum, so any given point on the loop only has half the cooling power it could have. Jan 11, 2018 · I'm having issues when setting up a "closed (infinite) loop gas pipe" in Oxygen Not Included. Keep generators heat buildings far away, temp arround 25C is good (mirth leaf 20C) There are two main options regarding SPOMs and cooling: Cool down the oxygen before it enters your base. I have built a cooling loop with 3 aquatuners. Mar 5, 2019 · For true early game water cooling, it's best to use the thermo aquatuner for water coming out of water sieves, but if you acquire any water hotter than 40 C it's typically a better idea to save that away from your base and use it for your electrolyzers later, as electrolyzers emit their oxygen and hydrogen at a 70C no matter what temp the water is, so it's usually best to use your hot water Cool your entire base instead. If you used a cooling loop, the loop needs to be cold enough to cool all the robominers because the water cools the robominers sequentially, not Feb 1, 2024 · So, I built a pair of Aquatuners around a Cool Steam Vent with 2 Steam Turbines above. The hydrogen would be connected to the liquid airlock, which would be connected to the steam. Was a nice warming zone for my initial cooling (heating?) loop until I got my refinery up and running and injecting 40-60'C water into my loop. And you will see you need alot to cool down oxygen from 70c. You need more mass or better SHC or both if there is still not enough cooling. To cool O2 coming out of SPOM you need 2 metal tiles per output. Reply reply Jul 30, 2023 · I am starting to learn how the whole SHC e TC mechanics work and I am still very confused. This design uses a conductive door controlled by a thermo sensor to keep a body of liquid at the desired temperature. looked for this all over for the last hours but couldn’t find any information. For base cooling, pwater is 99% of the time the best coolant. For example, running pipes with material that has high heat transferability like sediment rock. I'm planning to upgrade my system and make better contents in the future, please bare with me on the Oct 5, 2018 · The problem with that build is that the polluted water gets sent to the Sieve regardless of it's temperature. Im in a sticky situation. The second pool also has radiant pipes of another cooling loop, but this cooling loop will be cooled only by the two pools. I used 2 gas shut offs a gas thermo sensor, basically one to the tuner and the other to the loop missing the tuner with 2 automation wires from the sensor one going via a not gate. Hey Youtube! Cooling can be complicated and confusing in Oxygen Not Included. Since it only generates surplus cooling, it will produce about 16. I hope that this video gives you the basics to how to start cooling your base, When sending the water from the Steam Turbine back into the room with the Aquatuner to get turned back into steam how do you prevent this insulated pipe from breaking? After so many cycles the part of the insulated pipe that's right next to the liquid output starts to break. my base is running low on oxygen atm. Now after producing around 3t of refined copper the pool itself (7×5 squares) is still at 30° but the water in the tank for cooling is now at You need to fill the loop with exact amount of liquid so it does not have any more then 1kg in each given segment making reservoir redundant. I agree about not worrying too much at this stage and cooling the oxygen, but I would advise getting digging. May 7, 2020 · you can see that the aquatuner is saying that the pipe is blocked but the pipe segment that i am hovering with the mouse is empty also loop is not flowing smoothly it kinda chugs or pauses at each bridge as if it needs to see an empty pipe on the output of each bridge instead of just filling the Aug 14, 2019 · Wheezeworts aren't sufficient if you're producing significant power. If you have a liquid reservoir on your cooling loop, it should be placed as So if you get enough Ethanol for a cooling loop, you can achieve something like this: Before you even get access to gold. The rest of my base is around 20 degrees and is passively cooled (my sleetwheat farm is also being cooled by the same cool salt slush), but when it’s dormant, my sleetwheat farm overheats. Oct 27, 2021 · Hi all, can someone help me with this, I don't know if it is a bug and if so is there a workaround. The problem is when the aquatuner work as the packet alternate between the aquatuner and the bypass route. Room cooling with polluted water is more efficient due to bigger thermal conductivity - you can easily keep the room at -5° with polluted water and spend less energy for that. If it's free-flowing, there's simply no packet at the input. If you just use conveyors (or any transport system) the movement will stop eventually as the line becomes clogged. This being said, I do cool the oxygen pumped into my exosuit docks to 20C via an aquatuner controlled secondary reservoir (another 48,000kg) just outside my base purely so Anti entropy thermo-nullifier cooling loop. But I was wrong. Apr 7, 2018 · You could cool much easier by placing the electrolyzers directly above my above pictured cooling loop system, which is also 'dealing with heat problems at the source'. I thought this cooling loop is perfect. I have hit a point where the liquid just won't flow. Let's build the perfect base for our dupes, including a 5-star h This guide demonstrates options to deal with the massive heat produced by refining metals. You can use oni cooling calculator to see how many you need to cool your oxygen. i suspect that this will stop heat from going into my base making a cold barrier but wil the isolated tiles also leak cold to the surrounding tiles over times or are the too "isolated" for this Not exactly, what I had in mind there was just cooling the hydrogen, pumping it through the base, and then feeding it back to the cooling room (with the wheezeworts). Being fairly early game, I haven't had much use for the oil yet, but I think I've gathered 6 tons in 1 spot with a handful of wild Slicksters gradually adding to that. And you need to put the shutoff on the loop as well. All robominers get the same water and the water is sucked away into vacuum. This tutorial bite for Oxygen Not Included explains how to include the oxygen! It covers early oxygen production, Self Powered Oxygen Machines (SPOMs) and ca Mar 22, 2022 · Leave a like and a sub would help me a lot. Pump hot oxygen into your base and instead run a cooling loop through your base. Second, even you manage to cool down your oxygen (lets said 20c), it wont cool off the room you sent them to. Then (assuming your coolant is all the same liquid), whenever it detects there's a space in the loop, it lets more coolant back in. A self cooling ST/TA can easily stable at 98C and work for infinite cycles. Cooling loop for your farm is always a better and faster solution. Do you run cooling pipes through the base and not cool the oxygen? Yes! Oxygen is a gas with a really low specific heat capacity, which means it doesn't hold much heat, even if the temperature is high. water in that case. Water of whatever temperature is equally splitting itself between leaving the loop (sometimes after only having passed the aquatuner once) or actually entering the aquatuner a second time. If you have hydroponic tiles, run your cooling loop through your water supply. The cooling system room powers the steam turbine, which coverts some of the heat back into power. i also found two really close aetn to the right of my base. (If I have a small colony, I usually use a combination of the two: I have a cooling loop that runs through my base and that also passes through my SPOM, cooling It is different. The second pool also has a temperature sensor for opening the door between the both pools when the second pool is not cold enough. I built my first cooling loop in my current game on cycle 400, but then I have isolated heat on other places and are making my oxygen from really cold water (as that was the closest source). For green ports, go in to the rightmost bridge port, then to the other one, then end at the aquatuner. Other options for cooling include. -1 : receiving packet. Aug 11, 2021 · So i've setup a cooling loop arround a hot water geyser to produce clean water at base friendly temperatures. Maybe Petroleum? Funnily enough, Francis does not mention the liquid pump version in the tutorial nugget itself, he just brushes over it saying something "it's nothing new I haven't showed yet" while explaining how much cooling can 1 AT do. Sep 25, 2022 · An ONI series with the Spaced Out DLC. ) Do not build a conveyor that enters the loop directly but leave a space and have the incoming material use a bridge to enter the loop. make a cooling loop - with radiant pipes in the critical areas. If the system locks up, the cooling loop will continue to cool the gas until it turns to liquid and breaks the system. If other designs prove too challenging this is a working, foolproof alternative for early Feb 1, 2024 · I'm using petroleum coolant for a metal refinery with the standard aquatuner setup. Jun 8, 2023 · Oxygen Not Included allows players to manage their Duplicants and help them dig, build and maintain a subterranean asteroid base. Sep 22, 2019 · I just disconnect the coolant supply manually when I am happy with my loop, but if you really want to automate it and leave the supply pipe in place, then put a liquid sensor in the last segment of the cooling pipe just before it loops back to the supply point (I would connect the supply to the in port of the buffer tank, and then place the What the hell are you guys talking about cooling steam turbine "room". (But you can of course use the same designs to cool whatever. This is a very simple version that cools what you hook up to the cooling se This is a nice build! Definitely one of the first ones new players should get down. The first Aquatuner is working fine; it's circulating polluted water through my power generation area, keeping 6 Coal Generators, 4 Natural Gas Generators, and 2 Petroleum Generators at about 45°F (~7°C). The cooling loop will ultimately dump its heat into an aquatuner room. I am using one to cool the whole base and oxygen, not a single issue A fairly simple approach to taming metal volcanos in Oxygen Not Included. If you need spot cooling because you done goofed, build an ice tempshift plate touching the farm Nov 24, 2019 · Like the title says. The wiki you quoted is 100% correct. but when it turns back to steam, its going to be sucked back into the So you may not need the sensor on the pipe if the temperatures you're working with are high enough (25C) and the heat to be removed isn't that much. Main problem is that the loop is not always fully saturated with this, especially if your input is not fully saturated, but also if your release point from the loop is far away from where you test this. Jan 3, 2025 · So I am doing my first cooling loop and I am having a stasis problem. ) Jul 25, 2020 · So I use a perimeter cooling loop running through my central clean water reservoir (approximately 80,000kg) kept at 25C by a combination of melted ice and a liquid tepidizer. It won't be, making the net cooling even stronger. Thermo sensor: below [temperature you want coolant to be] If you want to use a cold geyser to cool your base but you want control over the temperature you need an intermediate step. I'm not sure what I need to fix it. The main reasons for high temperatures are geyser water and machine heat, as you will need both through your game to keep your dupes alive. The cooler the polluted water that gets sent to the sieve, the less efficient the system is resource-wise (here it is using CO2). That works fine. The heat from room will just heat oxygen in no time. 2 W of power produced. -2 : cooling the packet and releasing it. Then, that coolant liquifies the ethanol gas, heating it back up by a little bit less, creating a net cooling effect. I tend to use two designs, one version for cooling either SPOM oxygen output or the liquid in a cooling loop. How are you guys building your loops? The first sensor is set to above 40C, the second is set to above 25C, the third t I use my Spom oxygen cooling ST/TA to cool whole base. Dec 2, 2021 · A lot of tutorial for such a tiny device. Depends on how much heat you need to deal with. Now, I have created my aquatuner cooling loop multiple times following this guide, but it is not working. It's not super energy efficient, but you can build it without steel, and can create a LOT of cooling if you tune it precisely. I'm assuming it's because the water is getting turned into steam while still inside the pipe just before it's actually Jul 1, 2018 · Ok, shooting from the hip before I head to bed but I think you're using an idea I have used cooling oxygen to the right temp on a single thermowhatsit. If the bypass is longer than the main path, then you have an even worse problem: there isn't enough room for all of the liquid when the AT turns on and so the pipe clogs. Then you run a pipe through that same spot. But If u want to cool liquid using cooling loop the BEST material is WOLFRAMITE, but GRANITE is the next best choice. See the cooling loop runs across a single tempshift plate. The ice box sensor can be set at 22-23C, the pwater in the AT loop runs in the 4-20C range, packets in the cooling loop leave the box at 24-25C. Aug 2, 2019 · If you are cooling water to cool your oxygen, make a close loop and and use a liquid pipe thermo sensor to enable/disable the aquatuner depending on the temperature the water is. (Or don't use domestic farm and use wild farm/ranching instead) May 23, 2020 · Also you used Oxygen, which has low SHC of 1. Dec 10, 2022 · Using a bridge to fill the loop should prevent it from becoming over-full, so the other reason why it might not be flowing is ambiguous flow direction. That means, if you load up 1. im not in space yet, so what's 2nd best for cooling Feb 23, 2020 · I want to make a cooling loop with a steam turbine, but was wandering what liquid to put in the basin where my thermoaquatuner is? I was going to use crude oil, but now I'm wondering if there is a liquid that is even better to 'store' my heat in? Maybe ethanol or naphta? Secondly, what would be a good liquid to use in the cooling loop itself? Aside from the usual pwater. But occasionally after a couple of cycles running just fine, the pipes suddenly block. Members Online Presenting 'GameBreaker' My 6861 cycle old base that I'm abandoning because its unstable and runs at 6 FPS even with fasstrack. In the end the cooling loop would cool the steam, and it could boild and flash in the pipes. i have a cool steam vent somewhat near to the left of my base. TL;DR: Have the overflow bypass enter the loop directly near the AT output. Thermo sensor: below [temperature you want coolant to be] Nov 25, 2018 · That temp sensor is set to an arbitrary value, I have it at 40C. Jan 16, 2020 · If the main path is longer than the bypass, then you get a gap in your loop with no liquid in it since the loop is now longer than it was when it was taking the bypass. I resolve this issue with a NOT gate and a liquid shutoff on the bypass route. All Discussions Screenshots Artwork Broadcasts Videos Workshop News Guides Reviews Just trying to make a simple cooling loop with an your answers dont seem to be properly answered, the reason your steam is moving away from your aquatuner is simply because where your liquid vents are, the steam turbines act like a vacuum to suck in the steam. the reservoir is a safety buffer for coolant because the radiant pipes are made of gold/copper, if they were made of aluminum or something better it would be possible, with a couple of adjustment. But, if you want to run a cooled farm for plants, the AT-ST approach is best. However, if you decide you want to modify the cooling loop by adding more pipe, you need to add more p. You want a single continuous loop, you only need one temp sensor, as close to the aquatuner's input side as possible. The new (for me, at least) idea is to cool the oxygen in the hydrogen room via radiant pipes, and then use that oxygen to cool the base via radiation (from pipes) and from feeding Oct 9, 2019 · very usefull , even if i only made it past turn 200 several time's, now would it be better to store the cooled water , as liqued containers as far as i now, dont loose heat So this nets cooling and polluted dirt while also producing around 200-300kg per cycle of oxygen (no it's not enough oxygen on its own, dupes use 100kg per cycle BUT by using the polluted dirt solely from the output of this in a sublimation station you will net consistently 800kg to 900kg oxygen per cycle which CAN support 8-9 dupes). 005. You want anywhere between 10-100k of steam per tile. so they're draining the steam away. Setup… Actually I did get a bit excited about ethanol having such a low freezing point. A simpler loop with less automation will work better, and is easier to build. You need a clear cooling loop, ie in all pipe segments all white sockets should be on one side of this segment and green on the other. The second version for cooling sleet wheat farms. I don't pretend to really understand these builds, but one thing stuck out. Thanks folks. First, wheezewort cooling are retively small. Issue is, the whole area got pretty hot pretty quick and now the geser's been dormant for 20+ cycles, but the air, water and With "batch" processes things can be a bit more complicated. Instead of running the water directly, make a "cool battery" by cooling a large pool of the same output of the geyser (brine or PWater) then use a "cool injector", basically a second pool of water with a Thermo sensor, separated from the "cool battery" by a mechanic Oct 9, 2019 · Hey everyone,since I'm using it for a lot of my designs, I thoughts its time to give the aqua tuner cooling loop its own video. That can last a long time. You can't get liquid hydrogen and oxygen with ethanol. The cooling loop uses a bridge to force circulation even when the regulator is disabled. The still cold liquid is then sent over a liquid bridge back into the cooling line to pick I’m looking for a simple cooling loop design to chill my sleetwheat farm. 895DTUs of heat into the turbine. Could y’all point me to a couple good designs I can use. Mar 2, 2018 · So this topic is bit hot now, Neotuck showed us that if u want to make radiator (that cooling down area or heating up area) SEDIMENTARY ROCK or Obsidian is the best choice. Aug 31, 2021 · hello everyone! i’m pretty new to the game. 2kw !). Make ice because "why not" - Ice Maker more efficient, because it deletes some heat energy entirely. This particular design doesn't have much throughput but once set up, doesn't require any further attention or tweaking. Pump melted water to refinery in don’t back into pool. End Screen music: When Johnny Comes Marching Home by Cooper Cannell---Coordinates: V-SFRZ-C-469570110-8VW3Mods:Show Other cases where gas loop cooling is good is small amounts of spot cooling, like cooling a few mealwood plants growing in a Drecko ranch, Dreckos run hot and temperatures trend towards 40 C, but a few kDTU/s can selectively keep farm tiles in a CO2 pit cool and a Thermo Regulator suffices. What you'll do is create the entire cooling loop out of pipes. World Seed: SNDST-C-315500929-0Mods I use:Plie The aquatuner boils the ethanol, cooling down the liquid in the pipes by some amount. Using both regulators or aquatuners lower packet temperature by constant 14C. Packets will ONLY exist at the input if the pipe backs up. I don't have any screenshots (trying to avoid the game lately as its addictive nature causes me to lose time). You have to put the liquid pipe thermo sensor right next to the input of the aquatuner though. Even if you're not doing a cooling loop, you can still turn valves or heat exchangers on or off depending on what temperature all the stuff is. This is not to be taken as I am talking bad about Francis, I love his content, his commentary, proficiency, but I am mildly Apr 5, 2020 · I've built this three times now. It's really hard to dial in just the right amount of flow and insulated/not insulated tiles and pipes to keep the temperature right. The added picture shows my conveyor loop, when its working. This looks like a good setup for poluted water, if I were you i would fill up those buffer liquid reservoir until half. If you have regular farm tiles, run it through those. Apr 6, 2021 · Oxygen Not Included. Oct 30, 2018 · I started a new game where I have a cool steam vent on either side of my base and slime around them as well. Follow my journey as I take on the next chapter of the Ultimate Base in Oxygen Not Included. Mar 29, 2020 · As Aquatuner take 2 ticks to cooling a packet of liquid. Difficult to manage, temperature might be the biggest challenge you will be facing in Oxygen Not Included. If the cooling liquid isn't moving, delete a section of pipe and rebuild it. Jan 25, 2022 · the most easy way in early game is just pump cold water through hot areas. The lesser the pressure , the faster it gets got, the more steam turbine operates. BUT as soon as the refinery starts needing fresh coolant, it pulls from the new cold water until the point that the cycled water hits the bridge at which point it take t Oct 5, 2021 · Hi guys. Start with a long a long pipe with a pump at the input and a gas vent at the output. 4 times as much power for the same amount of cooling that a polluted water cooling loop would do. Around you are lots of resources, free food, ice biomes (which you can use to cool oxygen later if you choose) etc. If cool starts getting too hot, use nearby ice to build a temp shift plates, they will immediately melt and cool the water back down. You shouldn't fill the cooling loop and liquid reservoir completely as that can cause the loop to stop circulating. does space have any sort of cooling factor? if i pipe water or gas up there, lay out some temp-shift or reactive tiles and loop back in, will it "stay cool" or is this a fluke temperature that will rise over time? basically: does space have an innate cooling factor on the area? or will it always gravitate toward heat because of no dissipation?. Usually the entire base doesn't need cooling, just some parts of it that make heat. The whole perimeter of the base pipes this PW. I create a system to bypass the aquatuner, the bypass work as expected. I decided to use the water they produce to make a slime pool, so I could dig out the whole biome without risk of having slimelung infected po2 everywhere. ) A metal refinery and cooling system for its input/output liquid, an aquatuner cooling loop to circulate a cooling liquid in your base, and a steam turbine to turn some of the heat generated by these machines into power. The insulated tile is made of Igneous Rock to inhibit heat exchange from the exterior to the tile. I saw that on Nathans box youtuber. Plus i s there such a thing as an anti-coolant? I have one submerged in a ph2o pool filled up with ph2o. Apr 9, 2021 · Except instead of cooling your base, you use the cooling loop to cool the steam into cool water. Maybe a polluted water loop that sneaks behind the crops. Especially as geysers shut down and your base grows. Is there a way For a loop to flow freely, all input ports must be clear of packets. 2t of coolant (because you kept it fed when you issued the first order), you need 40 free pipe segments on your cooling loop to allow the machine to function properly. Reply reply wyldmage Community for the space-colony simulation game Oxygen Not Included, developed by Klei. In a hydrogen atmosphere, they delete 12kDTU/s, so you need one for every 116. It's also possible that the fluid isn't flowing freely through the loop. 3% of the regular cooling, regardless of coolant. An ice biome. Like you said, putting an AT-ST in a steam box with a geyser (and not volcano - they are really hot!) and running a cooling loop from there should work fine. Also this is power expensive because of the Aquatuner (1. if you not have cold water then use some ice to cool the water down. These pipes are insulated ceramic pipes. As the polluted water passes through aquatuner the heat is displaced into a cooling system room. But for a normal base cooling loop, 15-20 kg per tile is fine. The water pool is around 30°. lidr fipnwg pckhxpa wzoo tplquz fnei bshb ontvc dkrc caqligtg